Volume 15, Issue 2 (2024)                   JMBS 2024, 15(2): 0-0 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Satari M, Hajipoor B, Hosseinkhani S, Abdolmaleki P. Investigating the effect of 50 Hz alternating magnetic field on nucleic acid delivery by magnetofection method. JMBS 2024; 15 (2)
URL: http://biot.modares.ac.ir/article-22-61658-en.html
1- Department of Biology, Faculty of Sciences, University of Malayer, Malayer, Iran , m.satari@modares.ac.ir
2- Department of Biophysics, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, Iran
3- Department of Biochemistry, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, Iran.
Abstract:   (581 Views)
Gene delivery using the force of a magnetic field is called magnetofection. The purpose of this study is the synthesis and characterization of magnetic iron oxide nanoparticles (Fe3O4) as the core of the transfer agent and to investigate the effect of alternating magnetic field on transfection efficiency. For this purpose, the first magnetic nanoparticles (MNP) were synthesized by coprecipitation method. The magnetic properties of the synthesized MNP were investigated by vibrating sample magnetometer (VSM), appearance characteristics, and zeta potential of the synthesized particles were evaluated  using transmission electron microscopy (TEM) and dynamic light scattering (DLS). Then, using magnetic nanoparticles (MNP), polyethylene imine (PEI) and plasmid DNA containing luciferase reporter gene (pDNA), PEI-pDNA binary complex and MNP-PEI-pDNA ternary complex were synthesized. The complexes were evaluated using DLS and gel retardation techniques. The results of DLS and gel retardation technique showed that the complexes have a suitable surface charge and polyethyleneimine is well joined to pDNA and neutralized its negative charge. Finaly, human breast cancer cell lines (MCF-7) and Hek293T cells were transfected by ternary complex in the presence of 50 Hz alternating magnetic field. Cell viability was measured using the MTT test. The obtained results showed that the transfection efficiency in the cells that were transfected with the ternary complex in the presence of alternating magnetic field increased significantly compared to the control group, without any additional toxicity (P ≤ 0.05).
 
Full-Text [PDF 1043 kb]   (348 Downloads)    
Article Type: Original Research | Subject: Molecular biotechnology
Received: 2022/05/20 | Accepted: 2024/05/15 | Published: 2024/06/24

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.