Volume 10, Issue 3 (2019)                   JMBS 2019, 10(3): 401-406 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Banimostafa arab M, Kushkestani S, Mehdizadehfar V, Sajedi H. Designing and implementation an Electrical Stimulation Device for Estimating Sound Perception in Cochlear Implant Candidates- Construct and Test. JMBS 2019; 10 (3) :401-406
URL: http://biot.modares.ac.ir/article-22-16965-en.html
1- Biomedical Engineering Department, New Science & Technology Faculty, Science & Research Branch, Islamic Azad University, Tehran, Iran, Floor 3, No. 9, Sepid Alley, Pour Mousa Street, Somayeh Street, Tehran, Iran , banimostafa.maryam@gmail.com
2- Biomedical Engineering Department, Engineering Faculty, Shahed University, Tehran, Iran
3- Bioelectric Department, Biomedical Engineering Faculty, Amirkabir University of Technology, Tehran, Iran
Abstract:   (5850 Views)
Transtympanic Promontory Stimulation Test (TPST) has been suggested to be a useful tool in predicting the effectiveness of cochlear implant surgery. This test is helpful for patients with poor auditory neuron functioning and individuals with a long auditory deprivation. It can provide a way to find a correlation between the dynamic range of the auditory nerve with the electrical dynamic range of the cochlear implant and estimate sound perception. In this study, an electrical stimulation device is designed and constructed that can produce stimulation with specific features. The device has two parts, hardware, and software. Software is designed as a user interface which installed on PC and helps the user to do a lot of operations for creating a desired electrical stimulation easily utilizing software menus. The data are transferred via serial port and network to hardware and finally, the stimulation is done through an active electrode that located in auditory canal and a passive electrode that can be placed on the mastoid or forehead. To ensure the proper functioning of the device, electrical tests have been done in different conditions. The results are shown that currently generated in a constant load resistance is linear and independent of load resistance.
Full-Text [PDF 882 kb]   (3015 Downloads)    
Subject: Agricultural Biotechnology
Received: 2016/10/9 | Accepted: 2016/12/30 | Published: 2019/09/21

References
1. Moore BCJ. An Introduction to the psychology of hearing. Amsterdam: Academic Press; 2003. [Link]
2. Lenhardt ML. Tinnitus Devices. In: Wnek GE, Bowlin GL, editors. Encyclopedia of biomedical engineering and biomaterials. Boca Raton: CRC Press; 2004. [Link]
3. Vernon JA, Fenwick JA. Attempts to suppress tinnitus with transcutaneous electrical stimulation. Otolaryngol Head Neck Surg. 1985;93(3),385-9. [Link] [DOI:10.1177/019459988509300318]
4. Alfelasi M, Piron JP, Mathiolon C, Lenel N, Mondain M, Uziel A, et al. The transtympanic promontory stimulation test in patients with auditory deprivation: Correlations with electrical dynamics of cochlear implant and speech perception. Eur Arch Otorhinolaryngol. 2013;270(6):1809-15. [Link] [DOI:10.1007/s00405-012-2125-1]

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.