Numerical analysis of the effect of three-dimensional scaffold structure on the distribution of mechanical factors on the surface of bone scaffold

Document Type : Original Research

Authors

1 Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran

2 Associate Professor, Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran.

Abstract
Evaluating the response of the stem cells to different mechanical stimulation is an important issue to obtain control over cell behavior in the culture environment. One of the effective parameters in the mechanoregulation of stem cells is the microstructure of scaffolds. Evaluating the effect of microstructure of scaffold in the lab environment is very complicated. Therefore, in this study, the effect of scaffold architecture on mechanical factors in the scaffold was investigated under oscillatory fluid flow by using numerical modeling. In this study, distribution of shear stress and fluid velocity in three types of scaffolds with spherical, cubical and regular hexagonal pores with length of 300, 350, 400, 450 and 500 micrometers were investigated by using computational fluid dynamics method. The results of the computational fluid dynamics model showed that the scaffold with spherical and cubic pores shape with length of 500 micrometers and scaffold with hexagonal pores with length of 450 micrometers experienced shear stress in the range of 0.1-10 mPa. This range of the shear stress is suitable for differentiation of the stem cell to bone cells. Moreover, the result of exerting oscillatory fluid flow to these scaffolds indicated that dead zones of the scaffold, where isn’t suitable for cell seeding, was decreased due to the access of fluid flow to the different area of scaffold. The results of this study can be used in a laboratory to achieve optimal stem cell culture to provide suitable environment culture for differentiation of stem cells toward the bone cell.

Keywords

Subjects


1. Moradkhani, M., Vahidi, B. & Ahmadian, B. Finite element study of stem cells under fluid flow for mechanoregulation toward osteochondral cells. J Mater Sci: Mater Med, 2021. 32 (7), P. 1-10.
2. Ali, D. and S. Sen, Permeability and fluid flow-induced wall shear stress of bone tissue scaffolds: computational fluid dynamic analysis using Newtonian and non-Newtonian blood flow models. Computers in Biology and Medicine, 2018. 99: p. 201-208.
3. Giannitelli, S., et al., Current trends in the design of scaffolds for computer-aided tissue engineering. Acta biomaterialia, 2014. 10(2).
4. Eghbali, H., et al., An experimental-numerical investigation on the effects of macroporous scaffold geometry on cell culture parameters. The International journal of artificial organs, 2017. 40(4): p. 185-195.
5. Hendrikson, W.J., et al., Influence of additive manufactured scaffold architecture on the distribution of surface strains and fluid flow shear stresses and expected osteochondral cell differentiation. Frontiers in bioengineering and biotechnology, 2017. 5: p. 6.
6. Boschetti, F., et al., Prediction of the micro-fluid dynamic environment imposed to three-dimensional engineered cell systems in bioreactors. Journal of biomechanics, 2006. 39(3): p. 418-425.
7. Malvè, M., D. Bergstrom, and X. Chen, Modeling the flow and mass transport in a mechanically stimulated parametric porous scaffold under fluid-structure interaction approach. International Communications in Heat and Mass Transfer, 2018. 96: p. 53-60.
8. Zhao, F., T.J. Vaughan, and L.M. Mcnamara, Multiscale fluid–structure interaction modelling to determine the mechanical stimulation of bone cells in a tissue engineered scaffold. Biomechanics and modeling in mechanobiology, 2015. 14(2): p. 231-243.
9. Zhao, F., T.J. Vaughan, and L.M. McNamara, Quantification of fluid shear stress in bone tissue engineering scaffolds with spherical and cubical pore architectures. Biomechanics and modeling in mechanobiology, 2016. 15(3): p. 561-577..
10. Chen, G., et al., Responses of MSCs to 3D scaffold matrix mechanical properties under oscillatory perfusion culture. ACS applied materials & interfaces, 2017. 9(2): p. 1207-1218.
11. Zadpoor, A.A., Bone tissue regeneration: the role of scaffold geometry. Biomaterials science, 2015. 3(2): p. 231-245.
12. Zhao, F., T.J. Vaughan, and L.M. McNamara, Quantification of fluid shear stress in bone tissue engineering scaffolds with spherical and cubical pore architectures. Biomechanics and modeling in mechanobiology, 2016. 15(3): p. 561-577.
13. Vaughan, T., M. Haugh, and L. McNamara, A fluid–structure interaction model to characterize bone cell stimulation in parallel-plate flow chamber systems. Journal of The Royal Society Interface, 2013. 10(81): p. 20120900.
14. Vaez Ghaemi, R., et al., Fluid–Structure Interactions Analysis of Shear‐Induced Modulation of a Mesenchymal Stem Cell: An Image‐Based Study. Artificial Organs, 2016. 40(3): p. 278-287.
15. Abbasszadeh Rad, A. and B. Vahidi, The Effect of the Kind of Attachment of Primary Cilium to Cell in Its Response to the Fluid Flow: A 3D Computational Simulation. Journal of Solid and Fluid Mechanics, 2018. 8(1 #HD00105): p. -.
16. Pritchard, P.J. and J.W. Mitchell, Fox and McDonald's introduction to fluid mechanics. 2016: John Wiley & Sons.
17. Rad, A.A. and B. Vahidi, A finite elements study on the role of primary cilia in sensing mechanical stimuli to cells by calculating their response to the fluid flow. Journal of Computational Applied Mechanics, 2016. 47(1): p. 35-44.
18. Abbasszadeh Rad, A.H. and B. Vahidi, The Effect of the Kind of Attachment of Primary Cilium to Cell in Its Response to the Fluid Flow: A 3D Computational Simulation. Journal of Solid and Fluid Mechanics, 2018. 8(1): p. 203-213.
19. Olivares, A.L., et al., Finite element study of scaffold architecture design and culture conditions for tissue engineering. Biomaterials, 2009. 30(30): p. 6142-6149.
20. Murphy, C.M., et al., Cell-scaffold interactions in the bone tissue engineering triad. Eur Cell Mater, 2013. 26(4): p. 120-132.
21. Murphy, C.M., et al., Mesenchymal stem cell fate is regulated by the composition and mechanical properties of collagen–glycosaminoglycan scaffolds. Journal of the mechanical behavior of biomedical materials, 2012. 11: p. 53-62.
22. McCoy, R.J., C. Jungreuthmayer, and F.J. O'Brien, Influence of flow rate and scaffold pore size on cell behavior during mechanical stimulation in a flow perfusion bioreactor. Biotechnology and bioengineering, 2012. 109(6): p. 1583-1594.